Reversed phase raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.
This page was last updated on 2025-12-20 and is reviewed periodically as new material appears.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
| Property | Value | Notes |
|---|---|---|
| Validation parameter | Accuracy | Closeness to a reference value. |
| Validation parameter | Precision | Repeatability or intermediate precision. |
| Validation parameter | Linearity | Proportional response across a range. |
| System suitability check | Resolution | Separation between adjacent peaks. |
| Quality control tool | Control chart | Tracks results over time for trends. |
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Weak affinity chromatography (WAC) is an affinity chromatography technique for affinity screening in drug development. WAC is an affinity-based liquid chromatographic technique that separates chemical compounds based on their different weak affinities to an immobilized target. The higher affinity a compound has towards the target, the longer it remains in the separation unit, and this will be expressed as a longer retention time. The affinity measure and ranking of affinity can be achieved by processing the obtained retention times of analyzed compounds. Affinity chromatography is part of a larger suite of techniques used in chemoproteomics based drug target identification. The WAC technology is demonstrated against a number of different protein targets – proteases, kinases, chaperones and protein–protein interaction (PPI) targets. WAC has been shown to be more effective than established methods for fragment based screening. Affinity chromatography was conceived and first developed by Pedro Cuatrecasas and Meir Wilchek.
The first symptom of CJD is usually rapidly progressive dementia, leading to memory loss, personality changes, and hallucinations. Myoclonus (jerky movements) typically occurs in 90% of cases, but may be absent at initial onset. Other frequently occurring features include anxiety, depression, paranoia, obsessive-compulsive symptoms, and psychosis. This is accompanied by physical problems such as speech impairment, balance and coordination dysfunction (ataxia), changes in gait, and rigid posture. In most people with CJD, these symptoms are accompanied by involuntary movements. Rarely, unusual symptoms like the alien limb phenomenon have been observed. The duration of the disease varies greatly, but sporadic (non-inherited) CJD can be fatal within months or even weeks. Most affected people die six months after initial symptoms appear, often of pneumonia due to impaired coughing reflexes. About 15% of people with CJD survive for two or more years. The symptoms of CJD are caused by the progressive death of the brain's nerve cells, which are associated with the build-up of abnormal prion proteins forming in the brain. When brain tissue from a person with CJD is examined under a microscope, many tiny holes can be seen where the nerve cells have died. Parts of the brain may resemble a sponge where the prions were infecting the areas of the brain.
Absorbance Units Full Scale (AUFS) or Absorption Units Full Scale is a unit of absorbance intensity that denotes the output of a spectrophotometer. The acronym AUFS can also be written out as Absorbance Units per Full Scale Deflection. AUFS is an arbitrary unit of the maximum ultraviolet or visible light absorbance intensity measured by a detector. It can be used in chemical analysis to quantify components in a mixture, as each component's integrated peak area corresponds to their relative abundance. AUFS is given as a number ranging from 0 to 1, where a measurement of 1 AUFS indicates an absorbance reading of 1 at full deflection. Analytical chemistry Chromatography Spectroscopy
Nanoghosts are nanosized vesicles containing a chosen drug delivery payload manufactured from extracted leukocyte membranes with the cell cytoplasm content removed. The use of biological membranes serves to mask the particles from the immune system to reduce the likelihood of an immunogenic response, as well as to extend circulation of the particles in the blood. They are produced by homogenizing the cells to remove the cytosol, and then sonicating the empty cell membranes to create nanoghosts between 100 and 200 nm in diameter. Membranes used to make nanoghosts harvested form red blood cells have been shown to circulate for about 120 days and avoid phagocytotic cells. Neutrophil based nanoghosts retain the chemotaxis capacity of neutrophils to sites of inflammation, which encourages tumor targeting. NK based nanoghosts exhibit metastatic cancer targeting behavior. Monocyte based nanoghosts are effective at infiltrating the tumor microenvironment. Mesenchymal stem cell derived nanoghosts exhibit cancer targeting properties.
The first symptom of CJD is usually rapidly progressive dementia, leading to memory loss, personality changes, and hallucinations. Myoclonus (jerky movements) typically occurs in 90% of cases, but may be absent at initial onset. Other frequently occurring features include anxiety, depression, paranoia, obsessive-compulsive symptoms, and psychosis. This is accompanied by physical problems such as speech impairment, balance and coordination dysfunction (ataxia), changes in gait, and rigid posture. In most people with CJD, these symptoms are accompanied by involuntary movements. Rarely, unusual symptoms like the alien limb phenomenon have been observed. The duration of the disease varies greatly, but sporadic (non-inherited) CJD can be fatal within months or even weeks. Most affected people die six months after initial symptoms appear, often of pneumonia due to impaired coughing reflexes. About 15% of people with CJD survive for two or more years. The symptoms of CJD are caused by the progressive death of the brain's nerve cells, which are associated with the build-up of abnormal prion proteins forming in the brain. When brain tissue from a person with CJD is examined under a microscope, many tiny holes can be seen where the nerve cells have died. Parts of the brain may resemble a sponge where the prions were infecting the areas of the brain.
Sources: en.wikipedia.org
Solid-liquid extraction based ambient ionization is based on the use of a charged spray, for example electrospray to create a liquid film on the sample surface. Molecules on the surface are extracted into the solvent. The action of the primary droplets hitting the surface produces secondary droplets that are the source of ions for the mass spectrometer. Desorption electrospray ionization (DESI) is one of the original ambient ionization sources and uses an electrospray source to create charged droplets that are directed at a solid sample. The charged droplets pick up the sample through interaction with the surface and then form highly charged ions that can be sampled into a mass spectrometer. Desorption atmospheric pressure photoionization (DAPPI) is a solid-liquid extraction ambient ionization method that enables the direct analysis of samples deposited on surfaces by means of a jet of hot solvent vapour and ultraviolet light. The hot jet thermally desorbs the sample from a surface and the vaporized sample is ionized by a vacuum ultraviolet light and consequently sampled into a mass spectrometer.
The major limitation in the development of artificial WBCs is the translation of the technologies into clinical approval and use. Other limitations include the availability of technology necessary to produce artificial WBCs, variability in yield, and difficulties in purifying the particles necessary for standard clinical use. Some studies have also found that these particles may unintentionally target other tissues that are otherwise healthy. The delivery of the therapies faces some difficulties in that too rapid administration might cause systemic side effects, whereas a too slow release would be less effective. A major limitation to polymersomes is that a select number of polymers such as polyethylene glycol and poly(lactic-co-glycolic acid) are approved by the FDA for clinical use. Nanoghosts, or more generally membrane-coated nanoparticles, experience limitations in that cells will have varying degrees of proteins present in their membranes, creating variability and lack of stability in those products. There also is the risk that membrane proteins essential to the biomimetic function of the nanoghosts can become denatured in the manufacturing and storage process. Overall, more studies need to be done on these biomimetic solutions to verify efficacy and safety.
From 2002 to 2004, Pinhasov carried out postdoctoral research at Johnson & Johnson Pharmaceutical Research and Development (Spring House, Pennsylvania, United States), where under the guidance of Dr. Douglas Brenneman he was engaged in the development of drugs for the treatment of neurodegenerative diseases. In 2005, Pinhasov joined the Department of Molecular Biology at Ariel University (formerly the College of Judea and Samaria) as an assistant professor. He was Head of the department from 2008 to 2014. In 2014, Pinhasov was appointed Vice-President and Dean of Research & Development at Ariel University, holding this position until 2020. In 2020 the Senate of Ariel University elected Professor Pinhasov as the Rector of Ariel University, succeeding Professor Michael Zinigrad, who held this office for 12 years. In September 2023, in recognition of his contribution to academic ties between Israel and Kazakhstan, the Senate of Astana Medical University (AMU) awarded Prof. Albert Pinhasov the title of honorary professor.
Similar structures include the 310 helix (i + 3 → i hydrogen bonding) and the π-helix (i + 5 → i hydrogen bonding). The α-helix can be described as a 3.613 helix, since the i + 4 spacing adds three more atoms to the H-bonded loop compared to the tighter 310 helix, and on average, 3.6 amino acids are involved in one ring of α-helix. The subscripts refer to the number of atoms (including the hydrogen) in the closed loop formed by the hydrogen bond.
Sources: en.wikipedia.org
On-line mass spectrometry was develop to solve some of the limitations and problem that develop from off-line analysis, such as evaporation and chemical reactions of particles in the filters during long analysis time. On-line Mass spectrometry solves these problems through the collection and analysis of aerosol particles in real time. On-line instruments are very portable and allow for spatial variability to be examined. These portable instruments can be put on many different platforms such as boats, planes, and mobile platforms (e.g. car trailers). An example of this is in the picture at the beginning with the instrumentation attached to an aircraft. Like off-line, on-line mass spectrometry has many different type of instruments, which can be broken up into two types; instruments that measures the chemistry of the particle ensemble (bulk measurement) and those that measure the chemistry of individual particles (single-particle measurement). Thus based on analytical need different instrumentation is used in analysis of the aerosol particles.
Alfred Stracher (1931-2013) was an American biochemist and the founder and editor-in-chief of Drug Delivery. During his lifetime, he was Distinguished Professor of Biochemistry at SUNY Downstate Medical Center. Alfred Stracher was born in Albany, New York in 1931. He graduated from Rensselaer Polytechnic Institute in 1952 with a Bachelor of Science in Chemistry. He received his PhD in Chemistry from Columbia University in 1956.
The main building of the Institute is located at the intersection of Kremlyovskaya and Lobachevskaya streets. This four-story building built in 1953 in the style of Soviet neoclassicism under the guidance of architect A.G. Bikchentaev. The building of the museum of Kazan chemical school is located in the campus of the main university building, built in the 1830s in a classical style under the guidance of architect M.P. Corinfskiy. In 2015 construction of a large laboratory building in the campus of Alexander Butlerov Institute of Chemistry was finished. The 7-storey building housed classrooms and laboratories of departments of Alexander Butlerov Institute of Chemistry, Institute of Geology and Petroleum Technologies, Institute of Physics. The building was constructed with the support of the President of Tatarstan R.N. Minnikhanov and PSC "TAIF".
Sources: en.wikipedia.org
Method validation is the documented process of showing that an HPLC procedure produces reliable results for a defined purpose. It examines parameters such as accuracy, precision, specificity, linearity, and robustness. Regulators and quality systems often require validation before routine use.
System suitability is a set of checks run on the chromatographic system before sample analysis. It confirms that resolution, peak shape, retention time, and response meet predefined limits. Failure can invalidate the run and trigger corrective action.
Blank injections reveal peaks or baseline disturbances that come from solvents, reagents, or the instrument rather than the sample. They help distinguish contamination from actual analyte signals. Comparing blanks with sample runs supports accurate interpretation.
System suitability is a set of checks that confirm the instrument and method perform within limits before sample analysis. It typically includes resolution, tailing factor, retention time, and peak area reproducibility. If a check fails, the run is invalidated until the cause is resolved.