This is a working overview of Retention time, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2025-09-19. Anything still debated is marked as such rather than presented as settled.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
It is thought that high glucagon levels and lack of insulin production are the main triggers for the metabolic issues associated with Type I diabetes, in particular maintaining normal blood glucose levels, formation of ketone bodies, and formation of urea. One finding of note is that the glucagon response to hypoglycemia is completely absent in patients with Type I diabetes. Consistently high glucagon concentrations in the blood can lead to diabetic ketoacidosis, which is when ketones from lipid breakdown build up in the blood, which can lead to dangerously low blood glucose levels, low potassium levels, and in extreme cases cerebral edema. It has been proposed that the reason for the high levels of glucagon found in the plasma of patients with Type I diabetes is the absence of beta cells producing insulin and the reciprocal effect this has on delta cells and the secretion of somatostatin.
The removal of dead cells by neighboring phagocytic cells has been termed efferocytosis. Dying cells that undergo the final stages of apoptosis display apoptotic-cell associated molecular patterns (ACAMPs), such as phosphatidylserine on the outer leaflet of the cell membrane. Phosphatidylserine is normally found on the inner leaflet surface of the plasma membrane, but is redistributed during apoptosis to the extracellular surface by a protein known as scramblase. These molecules mark the cell for phagocytosis by cells possessing the appropriate receptors, such as macrophages. The removal of dying cells by phagocytes occurs in an orderly manner without eliciting an inflammatory response. During apoptosis cellular RNA and DNA are separated from each other and sorted to different apoptotic bodies; separation of RNA is initiated as nucleolar segregation.
Parker was born in March 1938, and was the only daughter of Frederick and Hilda Witcomb (née Linscott). She was married to Joseph Parker, a Post Office engineer, and lived in the Kings Norton area of Birmingham. After several years as a police photographer, she joined the University of Birmingham Medical School, where she was employed as a medical photographer in the Anatomy Department. She often worked in a darkroom above the laboratory where research on smallpox viruses was being conducted.
A typical intracellular concentration of ATP is 1–10 μmol per gram of muscle tissue in a variety of eukaryotes. The dephosphorylation of ATP and rephosphorylation of ADP and AMP occur repeatedly in the course of aerobic metabolism. ATP can be produced by a number of distinct cellular processes; the three main pathways in eukaryotes are (1) glycolysis, (2) the citric acid cycle/oxidative phosphorylation, and (3) beta-oxidation. The overall process of oxidizing glucose to carbon dioxide, the combination of pathways 1 and 2, known as cellular respiration, produces about 30 equivalents of ATP from each molecule of glucose. ATP production by a non-photosynthetic aerobic eukaryote occurs mainly in the mitochondria, which comprise nearly 25% of the volume of a typical cell.
Treatments aiming to inhibit works to block specific caspases. Finally, the Akt protein kinase promotes cell survival through two pathways. Akt phosphorylates and inhibits Bad (a Bcl-2 family member), causing Bad to interact with the 14-3-3 scaffold, resulting in Bcl dissociation and thus cell survival. Akt also activates IKKα, which leads to NF-κB activation and cell survival. Active NF-κB induces the expression of anti-apoptotic genes such as Bcl-2, resulting in inhibition of apoptosis. NF-κB has been found to play both an antiapoptotic role and a proapoptotic role depending on the stimuli utilized and the cell type. The progression of the human immunodeficiency virus infection into AIDS is due primarily to the depletion of CD4+ T-helper lymphocytes in a manner that is too rapid for the body's bone marrow to replenish the cells, leading to a compromised immune system. One of the mechanisms by which T-helper cells are depleted is apoptosis, which results from a series of biochemical pathways:
Sources: en.wikipedia.org
Network Science, Part 5: Solvent-Accessible Surfaces AREAIMOL is a command line tool in the CCP4 Program Suite for calculating ASA. NACCESS solvent accessible area calculations. FreeSASA Open source command line tool, C library and Python module for calculating ASA. Surface Racer Oleg Tsodikov's Surface Racer program. Solvent accessible and molecular surface area and average curvature calculation. Free for academic use. ASA.py — a Python-based implementation of the Shrake-Rupley algorithm. Michel Sanner's Molecular Surface – the fastest program to calculate the excluded surface. pov4grasp render molecular surfaces. Molecular Surface Package — Michael Connolly's program. Volume Voxelator — A web-based tool to generate excluded surfaces. ASV freeware Analytical calculation of the volume and surface of the union of n spheres (Monte-Carlo calculation also provided). Vorlume Computing Surface Area and Volume of a Family of 3D Balls. GetArea Calculate solvent accessible surface area of proteins online. ProMS ProMS - Protein Molecular Surface Calculator
This type of specificity is sensitive to the substrate's optical activity of orientation. Stereochemical molecules differ in the way in which they rotate plane polarized light, or orientations of linkages (see alpha, beta glycosidic linkages). Enzymes that are stereochemically specific will bind substrates with these particular properties. For example, beta-glycosidase will only react with beta-glycosidic bonds which are present in cellulose, but not present in starch and glycogen, which contain alpha-glycosidic linkages. This is relevant in how mammals are able to digest food. For instance, the enzyme Amylase is present in mammal saliva, that is stereo-specific for alpha-linkages, this is why mammals are able to efficiently use starch and glycogen as forms of energy, but not cellulose (because it is a beta-linkage). Specific equilibrium dissociation constant for formation of the enzyme-substrate complex is known as k d {\displaystyle k_{d}}
Parker was born in March 1938, and was the only daughter of Frederick and Hilda Witcomb (née Linscott). She was married to Joseph Parker, a Post Office engineer, and lived in the Kings Norton area of Birmingham. After several years as a police photographer, she joined the University of Birmingham Medical School, where she was employed as a medical photographer in the Anatomy Department. She often worked in a darkroom above the laboratory where research on smallpox viruses was being conducted.
Prior to the Air Pollution Control Act of 1955, little headway was made to initiate this air pollution reform. U.S. cities Chicago and Cincinnati first established smoke ordinances in 1881. In 1904, Philadelphia passed an ordinance limiting the amount of smoke in flues, chimneys, and open spaces. The ordinance imposed a penalty if not all smoke inspections were passed. It was not until 1947 that California authorized the creation of Air Pollution Control Districts in every county of the state.
In botany, apical dominance is the phenomenon whereby the main, central stem of the plant is dominant over (i.e., grows more strongly than) other side stems; on a branch the main stem of the branch is further dominant over its own side twigs. Plant physiology describes apical dominance as the control exerted by the terminal bud (and shoot apex) over the outgrowth of lateral buds.
Sources: en.wikipedia.org
Class A (or 1) (Rhodopsin-like) Class B (or 2) (Secretin receptor family) Class C (or 3) (Metabotropic glutamate/pheromone) Class D (or 4) (Fungal mating pheromone receptors) Class E (or 5) (Cyclic AMP receptors) Class F (or 6) (Frizzled/Smoothened) More recently, an alternative classification system called GRAFS (Glutamate, Rhodopsin, Adhesion, Frizzled/Taste2, Secretin) has been proposed for vertebrate GPCRs. They correspond to classical classes C, A, B2, F, and B. An early study based on available DNA sequence suggested that the human genome encodes roughly 750 G protein-coupled receptors, about 350 of which detect hormones, growth factors, and other endogenous ligands. Approximately 150 of the GPCRs found in the human genome have unknown functions. Some web-servers and bioinformatics prediction methods have been used for predicting the classification of GPCRs according to their amino acid sequence alone, by means of the pseudo amino acid composition approach. GPCRs are involved in a wide variety of physiological processes. Some examples of their physiological roles include:
Arginylglycylaspartic acid (RGD) is the most common peptide motif responsible for cell adhesion to the extracellular matrix (ECM), found in species ranging from Drosophila to humans. Cell adhesion proteins called integrins recognize and bind to this sequence, which is found within many matrix proteins, including fibronectin, fibrinogen, vitronectin, osteopontin, and several other adhesive extracellular matrix proteins. The discovery of RGD and elucidation of how RGD binds to integrins has led to the development of a number of drugs and diagnostics, while the peptide itself is used ubiquitously in bioengineering. Depending on the application and the integrin targeted, RGD can be chemically modified or replaced by a similar peptide which promotes cell adhesion.
A chromogranin A-derived antifungal peptide (CGA 47–66, chromofungin) when embedded on a surface has been shown to have antifungal activity by interacting with the fungal membrane and thereby penetrating the cell. Additionally, in vitro studies have demonstrated that such an antifungal coating can inhibit the growth of yeast Candida albicans by 65% and completely stop the proliferation of filamentous fungus Neurospora crassa. Copper and copper alloy surfaces have demonstrated a die-off of Aspergillus spp., Fusarium spp., Penicillium chrysogenum, Aspergillus niger and Candida albicans fungal spores. Hence, the potential to help prevent the spread of fungi that cause human infections by using copper alloys (instead of non-antifungal metals) in air conditioning systems is worthy of further investigation. The physical topology of a surface will determine the viable environment for bacteria. It may affect a microbe's ability to adhere to its surface. Textile surfaces tend to be very easy for microbes to adhere to due to the abundance of interstitial spacing between fibers.
In plants, nitrogen is first assimilated into organic compounds in the form of glutamate, formed from alpha-ketoglutarate and ammonia in the mitochondrion. For other amino acids, plants use transaminases to move the amino group from glutamate to another alpha-keto acid. For example, aspartate aminotransferase converts glutamate and oxaloacetate to alpha-ketoglutarate and aspartate. Other organisms use transaminases for amino acid synthesis, too. Nonstandard amino acids are usually formed through modifications to standard amino acids. For example, homocysteine is formed through the transsulfuration pathway or by the demethylation of methionine via the intermediate metabolite S-adenosylmethionine, while hydroxyproline is made by a post translational modification of proline. Microorganisms and plants synthesize many uncommon amino acids. For example, some microbes make 2-aminoisobutyric acid and lanthionine, which is a sulfide-bridged derivative of alanine. Both of these amino acids are found in peptidic lantibiotics such as alamethicin. However, in plants, 1-aminocyclopropane-1-carboxylic acid is a small disubstituted cyclic amino acid that is an intermediate in the production of the plant hormone ethylene.
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.