If you have been reading about retention time and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2025-07-10. Where a claim depends on a specific study, the study is described rather than over-claimed.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
| Property | Value | Notes |
|---|---|---|
| Validation parameter | Accuracy | Closeness of measured value to accepted reference value |
| Validation parameter | Precision | Agreement among repeated measurements under specified conditions |
| System suitability check | Resolution ≥ 1.5 | Baseline separation between critical peak pair |
| System suitability check | Tailing factor ≤ 2.0 | Common target for peak symmetry |
| Documentation | Validation report | Summarizes experiments, acceptance criteria, and conclusions |
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Vaginal rings are most commonly used for birth control purposes but can also be used to release compounds that treat and prevent STDs as well. The rings come in one standard size that fits most women and are made of flexible materials that contain the desired compound, whether that be hormones for birth control or other compounds for STD treatment. These substances are then slowly released over an extended period of time, typically a month. This is a convenient drug delivery method because they can easily be inserted and removed and do not prohibit intercourse. For birth control purposes, the vaginal ring is removed after 3 week and a new one is inserted a week later. Vaginal rings are also often used to treat symptoms of menopause, and these rings are replaced after a 3 month use. STD prevention and treatment through the use of vaginal rings is a newer application of such a device, but holds an advantage as a low maintenance option for women in areas with less access to regular healthcare.
5-Oxo-ETE and 5-oxo-15(S)-hydroxy-ETE but not 5-hydroxy members of the 5-HETE family such as 5-(S)-HETE activate peroxisome proliferator-activated receptor gamma (PPARγ). This activation does not proceed through OXER1; rather, it involves the direct binding of the oxo analog to PPARγ with 5-oxo-15-(S)-hydroxy-ETE being more potent than 5-oxo-ETE in binding and activating PPARγ. The Activation of OXER1 receptor and PPARγ by the oxo analogs can have opposing effects on cell function. For example, 5-oxo-ETE-bound OXER1 stimulates whereas 5-oxo-ETE-bound PPARγ inhibits the proliferation of various types of human cancer cell lines; this results in 5-oxo-ETE and 5-oxo-15-(S)-HETE having considerably less potency than anticipated in stimulating these cancer cells to proliferate relative to the potency of 5-(S)-HETE, a relationship not closely following the potencies of these three compounds in activating OXER1. 5-Oxo-ETE relaxes pre-contracted human bronchi by a mechanism that does not appear to involve OXER1 but is otherwise undefined.
Outbreaks of disease Food-born illness Bioterrorism Natural disasters APHL plays a critical role in crisis response to these public health emergencies through the Laboratory Response Network (LRN). The LRN was formed in 1999 in a cooperative effort between APHL, the CDC and FBI to rapidly detect, and respond to public health emergencies. The Department of Defense has joined in the effort to support biological response activities. In addition to their leadership during times of crisis, APHL has a strong focus on preparing public health laboratories on how to respond to emergencies when they happen through training and capacity-building, as well as creating model frameworks that labs around the country can use in order to have procedures in place to handle a crisis when it happens.
Greater emphasis on risk management Introduces “Special Requirements” Introduces “Critical Items” Measure: Requirements conformance Measure: Delivery performance Adopt proven product development processes Eliminate “recurring corrective actions” AS9100 Revision C was released in January, 2009, with considerable delay in application of the new version in audits, largely due to the delay in the release of AS9101 Revision D and auditor training to the increased auditing rigor of that update. AS9100 Revision D (2016), Quality Management System – Requirements for Aviation, Space and Defense Organizations The update of AS9100 from revision C to D includes the full text of ISO 9001:2015. In addition to aligning the structure of the aviation, space and defense requirements to the new structure of ISO 9001:2015, the following key changes were implemented:
Sources: en.wikipedia.org
ACTA2 (actin alpha 2) is an actin protein with several aliases including alpha-actin, alpha-actin-2, aortic smooth muscle or alpha smooth muscle actin (α-SMA, SMactin, alpha-SM-actin, ASMA). Actins are a family of globular multi-functional proteins that form microfilaments. ACTA2 is one of six different actin isoforms and is involved in the contractile apparatus of smooth muscle. ACTA2 (as with all the actins) is extremely highly conserved and found in nearly all mammals. In humans, ACTA2 is encoded by the ACTA2 gene located on 10q22-q24. Mutations in this gene cause a variety of vascular diseases, such as thoracic aortic disease, coronary artery disease, stroke, Moyamoya disease, and multisystemic smooth muscle dysfunction syndrome. ACTA2 (commonly referred to as alpha-smooth muscle actin or α-SMA) is often used as a marker of myofibroblast formation. Studies have shown that ACTA2 is associated with TGF-β pathway that enhances contractile properties of hepatic stellate cells leading to liver fibrosis and cirrhosis.
Yonath was accepted to Tichon Hadash high school since her mother could not pay the tuition, she traded her time teaching math lessons to students, which helped pay for her schooling. At a young age, she said, she was inspired by the scientist Marie Curie. However, she stressed that Curie, whom she as a child was fascinated by after reading her biography, was not her "role model". She returned to Jerusalem for college, graduating from the Hebrew University of Jerusalem with a bachelor's degree in chemistry in 1962, and a master's degree in biochemistry in 1964. In 1968, she obtained her PhD from the Weizmann Institute of Science for X-ray crystallographic studies on the structure of collagen, with Wolfie Traub as her PhD advisor. Yonath accepted postdoctoral positions at Carnegie Mellon University (1969) and MIT (1970). While a postdoctoral researcher at MIT she spent some time in the laboratory of subsequent 1976 chemistry Nobel Prize winner William N. Lipscomb, Jr. of Harvard University where she was inspired to pursue very large structures.
June 13 – 23: 2019 Men's Softball World Championship in Prague-Havlíčkův Brod Argentina defeated Japan, 3–2, to win their first Men's Softball World Championship title. Canada took third place. July 23 – 27: Europe/Africa Softball 2020 Olympic Qualifier in Utrecht Italy defeated Great Britain, 5–0, to book their team and compete at the 2020 Summer Olympics. July 26 – 30: 2019 Women's U12 Softball World Cup in Tainan (debut event) Chinese Taipei defeated Peru, 3–2, to win the inaugural Women's U12 Softball World Cup title. The Czech Republic took third place. Indonesia took fourth place. August 10 – 17: 2019 Women's U19 Softball World Cup in Irvine The United States defeated Japan, 4–3, to win their third consecutive and seventh overall Women's U19 Softball World Cup title. Canada took third place. August 25 – September 1: Americas Softball 2020 Olympic Qualifier in Surrey Champions: Mexico; Second: Canada; Third: Puerto Rico Note: Both Mexico and Canada have qualified to compete at the 2020 Summer Olympics. September 24 –28: Asia/Oceania Softball 2020 Olympic Qualifier in Shanghai Champions: Australia; Second: Chinese Taipei; Third: China Note: Australia has qualified to compete at the 2020 Summer Olympics.
Adenylyl-sulfate reductase (glutathione) (EC 1.8.4.9) is an enzyme that catalyzes the chemical reaction AMP + sulfite + glutathione disulfide ⇌ {\displaystyle \rightleftharpoons } adenylyl sulfate + 2 glutathione The 3 substrates of this enzyme are adenosine monophosphate, sulfite, and glutathione disulfide, whereas its two products are adenylyl sulfate and glutathione. This enzyme belongs to the family of oxidoreductases, specifically those acting on a sulfur group of donors with a disulfide as acceptor. The systematic name of this enzyme class is AMP,sulfite:glutathione-disulfide oxidoreductase (adenosine-5'-phosphosulfate-forming). Other names in common use include 5'-adenylylsulfate reductase (also used for, internal_xref(ec_num(1,8,99,2))), AMP,sulfite:oxidized-glutathione oxidoreductase, (adenosine-5'-phosphosulfate-forming), and plant-type 5'-adenylylsulfate reductase. In plants, APS is reduced by the plastidic enzyme APS reductase (APR; EC 1.8.4.9) in the presence of physiological concentrations of reduced glutathione (GSH), which acts as an electron donor.
BOP (benzotriazol-1-yloxytris(dimethylamino)phosphonium hexafluorophosphate) is a reagent commonly used for the synthesis of amides from carboxylic acids and amines in peptide synthesis. It can be prepared from 1-hydroxybenzotriazole and a chlorophosphonium reagent under basic conditions. This reagent has advantages in peptide synthesis since it avoids side reactions like the dehydration of asparagine or glutamine residues. BOP has used for the synthesis of esters from the carboxylic acids and alcohols. BOP has also been used in the reduction of carboxylic acids to primary alcohols with sodium borohydride (NaBH4). Its use raises safety concerns since the carcinogenic compound HMPA is produced as a stoichiometric by-product. PyBOP, a related phosphonium reagent for amide bond formation PyAOP, a related phosphonium reagent for amide bond formation
Sources: en.wikipedia.org
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.
Validation follows a planned protocol that tests accuracy, precision, specificity, linearity, range, detection limits, quantitation limits, and robustness. Results are compared against predefined acceptance criteria. The validation report supports regulatory filing or routine use.
Revalidation may be needed after changes to column chemistry, mobile phase, detection, sample preparation, or instrument type. It can also follow a pattern of out-of-specification results. The scope depends on whether the change affects method performance.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.