retention time comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2025-09-26. Where a claim depends on a specific study, the study is described rather than over-claimed.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
In biochemistry, two biopolymers are antiparallel if they run parallel to each other but with opposite directionality (alignments). An example is the two complementary strands of a DNA double helix, which run in opposite directions alongside each other. Nucleic acid molecules have a phosphoryl (5') end and a hydroxyl (3') end. This notation follows from organic chemistry nomenclature, and can be used to define the movement of enzymes such as DNA polymerases relative to the DNA strand in a non-arbitrary manner.
The role of inflammation in cancer is not well understood. Some organs of the body show greater risk of cancer when they are chronically inflamed. While there is an association between increased levels of C-reactive protein and risk of developing cancer, there is no association between genetic polymorphisms influencing circulating levels of CRP and cancer risk. In a 2004 prospective cohort study on colon cancer risk associated with CRP levels, people with colon cancer had higher average CRP concentrations than people without colon cancer. It can be noted that the average CRP levels in both groups were well within the range of CRP levels usually found in healthy people. However, these findings may suggest that low inflammation level can be associated with a lower risk of colon cancer, concurring with previous studies that indicate anti-inflammatory drugs could lower colon cancer risk.
There are many applications for AMS throughout a variety of disciplines. AMS is most often employed to determine the concentration of 14C, e.g. by archaeologists for radiocarbon dating. Compared to other radiocarbon dating methods, AMS requires smaller sample sizes (about 50 mg), while yielding extensive chronologies. MS technology has expanded the scope of radiocarbon dating. Samples ranging from 50,000 years old to 100 years old can be successfully dated using AMS, as other forms of mass spectrometry provide insufficient suppression of molecular isobars to resolve 13CH and 12CH2 from 14C atoms. Because of the long half-life of 14C, decay counting requires significantly larger samples. 10Be, 26Al, and 36Cl are used for surface exposure dating in geology. 3H, 14C, 36Cl, and 129I are used as hydrological tracers. Accelerator mass spectrometry is widely used in biomedical research. In particular, 41Ca has been used to measure bone resorption in postmenopausal women. List of accelerator mass spectrometry facilities Arizona Accelerator Mass Spectrometry Laboratory
CSF drug delivery refers to a number of methods designed to administer therapeutic agents directly into the CSF, bypassing the BBB to achieve higher drug concentrations in the CNS. This technique is particularly beneficial for treating neurological disorders such as brain tumors, infections, and neurodegenerative diseases. Intrathecal injection, where drugs are injected directly into the CSF via the lumbar region, and intracerebroventricular injection, targeting the brain's ventricles, are common approaches. These methods ensure that drugs can reach the CNS more effectively than systemic administration, potentially improving therapeutic outcomes and reducing systemic side effects. Advances in this field are driven by ongoing research into novel delivery systems and drug formulations, enhancing the precision and efficacy of treatments. Intrathecal pseudodelivery refers to a particular drug delivery method where the therapeutic agent is introduced into a reservoir connected to the intrathecal space, rather than being released into the CSF and distributed throughout the CNS. In this approach, the drug interacts with its target within the reservoir, allowing for changing the composition of the CSF without systemic release. This method can be advantageous for maximizing efficacy and minimizing systemic side effects.
ASBMB Award for Exemplary Contributions to Education ASBMB Leadership Awards ASBMB–Merck Award ASBMB Young Investigator Award Avanti Award in Lipids Bert and Natalie Vallee Award in Biomedical Science DeLano Award for Computational Biosciences Earl and Thressa Stadtman Distinguished Scientist Award Earl and Thressa Stadtman Young Scholar Award Herbert Tabor Research Award Mildred Cohn Award in Biological Chemistry - The Mildred Cohn Award in Biological Chemistry was established in 2013 to honor the scientific achievements of Mildred Cohn. Cohn was the first female president of the society, in 1978. The award of $5,000 is presented annually to a scientist who has made substantial advances in understanding biological chemistry using innovative physical approaches. The recipient is expected to deliver the Mildred Cohn Award lecture at the annual meeting. Ruth Kirschstein Diversity in Science Award The Alice and C. C. Wang Award in Molecular Parasitology Walter A. Shaw Young Investigator Award in Lipid Research William C. Rose Award
Sources: en.wikipedia.org
Isoforms I, III, and VIII are also stimulated by Ca2+/calmodulin. Isoforms V and VI are inhibited by Ca2+ in a calmodulin-independent manner. Isoforms II, IV and IX are stimulated by alpha subunit of the G protein. Isoforms I, V and VI are most clearly inhibited by Gi, while other isoforms show less dual regulation by the inhibitory G protein. Soluble AC (sAC) is not a transmembrane form and is not regulated by G proteins or forskolin, instead acts as a bicarbonate/pH sensor. It is anchored at various locations within the cell and, with phosphodiesterases, forms local cAMP signalling domains. In neurons, calcium-sensitive adenylyl cyclases are located next to calcium ion channels for faster reaction to Ca2+ influx; they are suspected of playing an important role in learning processes. This is supported by the fact that adenylyl cyclases are coincidence detectors, meaning that they are activated only by several different signals occurring together. In peripheral cells and tissues adenylyl cyclases appear to form molecular complexes with specific receptors and other signaling proteins in an isoform-specific manner.
The reaction catalyzed by 1-aminocyclopropane-1-carboxylic acid synthase (ACS) is the committed and rate-limiting step in the biosynthesis of ethylene [20], a gaseous plant hormone that is responsible for the initiation of fruit ripening, shoot and root growth and differentiation, leaf and fruit abscission, flower opening, and flower and leaf senescence. (source) It is a pyridoxal phosphate (PLP) dependent gamma-elimination (?). In the gamma elimination, PLP acts as a sink twice (absorbing electrons from two deprotonations). Proposed steps of the reaction mechanism: Formation of the ACS-PLP Schiff Base Imine Exchange Formation of the Quinonoid Intermediate Tyrosine and PLP stabilized 3C-Ring formation Formation of the ACS-PLP Schiff Base The aldehyde of coenzyme PLP reacts to form an imine (Schiff base) linkage with the catalytic domain lysine (278) residue of ACS. Imine exchange An imine exchange occurs, and the amine nitrogen of the substrate, S-Adenosyl methionine, replaces Lys (278) in the imine linkage. (Stabilized by H bonding).
Arrestins are elongated molecules, in which several intra-molecular interactions hold the relative orientation of the two domains. Unstimulated cell arrestins are localized in the cytoplasm in a basal inactive conformation. Active phosphorylated GPCRs recruit arrestin to the plasma membrane. Receptor binding induces a global conformational change that involves the movement of the two arrestin domains and the release of its C-terminal tail that contains clathrin and AP2 binding sites. Increased accessibility of these sites in receptor-bound arrestin targets the arrestin-receptor complex to the coated pit. Arrestins also bind microtubules (part of the cellular skeleton), where they assume yet another conformation, different from both free and receptor-bound form. Microtubule-bound arrestins recruit certain proteins to the cytoskeleton, which affects their activity and/or redirects it to microtubule-associated proteins. Arrestins shuttle between cell nucleus and cytoplasm. Their nuclear functions are not fully understood, but it was shown that all four mammalian arrestin subtypes remove some of their partners, such as protein kinase JNK3 or the ubiquitin ligase Mdm2, from the nucleus. Arrestins also modify gene expression by enhancing transcription of certain genes.
Corin converts the atrial natriuretic peptide (ANP) precursor, pro-ANP, to mature ANP, a cardiac hormone that regulates salt-water balance and blood pressure. In mice, corin deficiency prevents pro-ANP processing and causes salt-sensitive hypertension. Corin may also function as a pro-brain-type natriuretic peptide convertase. Corin-mediated ANP production in the pregnant uterus promotes spiral artery remodeling and trophoblast invasion. CORIN mutations have been reported in patients with preeclampsia. In mice, corin functions in the dermal papilla to regulate coat color in an Agouti-dependent pathway.
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
Method validation is the documented process of confirming that an HPLC procedure is suitable for its intended use. It evaluates accuracy, precision, specificity, linearity, range, detection limits, and robustness. Validation criteria depend on the regulatory context and the sample type.