Everything below concerns system suitability. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Updated 2025-02-26. Numbers and descriptions here follow the published literature rather than marketing material.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
| Property | Value | Notes |
|---|---|---|
| Primary guidance | ICH Q2(R2) | Analytical procedure validation |
| Compendial chapter | USP <621> | Chromatography general chapter |
| Validation parameter | Accuracy | Closeness to accepted true value |
| System suitability check | Peak resolution | Ensures separation between adjacent peaks |
| Data record | Audit trail | Supports data integrity and traceability |
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
Lewis acids have been classified in the ECW model and it has been shown that there is no one order of acid strengths. The relative acceptor strength of Lewis acids toward a series of bases, versus other Lewis acids, can be illustrated by C-B plots. It has been shown that to define the order of Lewis acid strength at least two properties must be considered. For Pearson's qualitative HSAB theory the two properties are hardness and strength while for Drago's quantitative ECW model the two properties are electrostatic and covalent. Monoprotic acids, also known as monobasic acids, are those acids that are able to donate one proton per molecule during the process of dissociation (sometimes called ionization) as shown below (symbolized by HA):
Anti-citrullinated protein antibodies (ACPAs) are autoantibodies (antibodies to an individual's own proteins) that are directed against peptides and proteins that are citrullinated. They are present in the majority of patients with rheumatoid arthritis. Clinically, cyclic citrullinated peptides (CCP) are frequently used to detect these antibodies in patient serum or plasma (then referred to as anti–citrullinated peptide antibodies). During inflammation, arginine amino acid residues can be enzymatically converted into citrulline residues in proteins such as vimentin, by a process called citrullination. If their shapes are significantly altered, the proteins may be seen as antigens by the immune system, thereby generating an immune response. ACPAs have proved to be powerful biomarkers that allow the diagnosis of rheumatoid arthritis (RA) to be made at a very early stage. In July 2010, the 2010 ACR/EULAR Rheumatoid Arthritis Classification Criteria were introduced. These new classification criteria include ACPA testing, and overruled the "old" ACR criteria of 1987 and are adapted for early RA diagnosis.
In addition to killing bacteria directly they have been demonstrated to have a number of immunomodulatory functions that may be involved in the clearance of infection, including the ability to alter host gene expression, act as chemokines and/or induce chemokine production, inhibiting lipopolysaccharide induced pro-inflammatory cytokine production, promoting wound healing, and modulating the responses of dendritic cells and cells of the adaptive immune response. Animal models indicate that host defense peptides are crucial for both prevention and clearance of infection. It appears as though many peptides initially isolated as and termed "antimicrobial peptides" have been shown to have more significant alternative functions in vivo (e.g. hepcidin). Dusquetide for example is an immunomodulator that acts through p62, a protein involved in toll like receptor based signalling of infection. The peptide is being examined in a Phase III clinical trial by Soligenix (SGNX) to ascertain if it can assist in repair of radiation-induced damage to oral mucosa arising during cancer radiotherapy of the head and neck.
Alfred Zack Gilman (February 5, 1908 – January 13, 1984) was an American pharmacologist best known for pioneering early chemotherapy techniques using nitrogen mustard with his colleague, Louis S. Goodman. The pair also published the classic textbook The Pharmacological Basis of Therapeutics in 1941, and Gilman served as an editor for its first six editions. Gilman served on the faculties of the Yale School of Medicine, the Columbia College of Physicians and Surgeons, and the Albert Einstein College of Medicine, where he founded the Department of Pharmacology. He was a member of U.S. National Academy of Sciences.
Human uses of AGPs include the use of Gum arabic in the food and pharmaceutical industries because of natural properties in thickening and emulsification. AGPs in cereal grains have potential applications in biofortification, as sources of dietary fibre to support gut bacteria and protective agents against ethanol toxicity. Arabinogalactan Proteoglycan This article was adapted from the following source under a CC BY 4.0 license (2021) (reviewer reports): Yingxuan Ma; Kim Johnson (2021). "Arabinogalactan-proteins" (PDF). WikiJournal of Science. 4 (1): 2. doi:10.15347/wjs/2021.002. Wikidata Q99557488.
Sources: en.wikipedia.org
ADAMTS7 was identified as a protease that binds and cleaves COMP in a yeast two-hybrid screen using the epidermal growth factor (EGF) domain of COMP as the bait. However, this initial finding has been contested; a 2025 study demonstrated that purified ADAMTS7 does not exhibit proteolytic cleavage activity toward purified COMP. Furthermore, three independent unbiased N-terminal amine isotopic labeling of substrates (N-TAILS) proteomic studies identified a number of candidate substrates for ADAMTS7 but did not identify COMP as a potential substrate. Consequently, there is as yet no scientific consensus on the physiological function of ADAMTS7. Tissue inhibitor of metalloproteinases 4 (TIMP-4) appears to be the physiological inhibitor of ADAMTS7.
“Chemoinformatics and Molecular Simulation”; “Chemistry of Supramolecular Nano- and Biosystems”; “Methods of Analytical Chemistry”; “Physical-Chemical Methods in Chemistry”; “Petrochemistry and Catalysis”. Total number of students taking Bachelor, Specialist and master's degree programs is 472 (as of January, 2016).Departments of the Institute of Chemistry educate postgraduates in the following majors: 02.00.01 – Inorganic Chemistry; 02.00.02 – Analytical Chemistry; 02.00.03 – Organic Chemistry; 02.00.04 – Physical Chemistry; 02.00.08 – Chemistry of Organoelement Compounds. There are two dissertation councils functioning in the Institute of Chemistry for thesis defence in chemical sciences: Д 212.081.03 under the Federal State Autonomous Institution of Higher Education “Kazan (Volga Region) Federal University”; majors allowed for defence: 02.00.01 – Inorganic Chemistry; 02.00.08 – Chemistry of Organoelement Compounds; Chairman of the Council is Professor Vladimir I. Galkin, Doctor of Chemistry;
Coiled-coil α helices are highly stable forms in which two or more helices wrap around each other in a "supercoil" structure. Coiled coils contain a highly characteristic sequence motif known as a heptad repeat, in which the motif repeats itself every seven residues along the sequence (amino acid residues, not DNA base-pairs). The first and especially the fourth residues (known as the a and d positions) are almost always hydrophobic; the fourth residue is typically leucine – this gives rise to the name of the structural motif called a leucine zipper, which is a type of coiled-coil. These hydrophobic residues pack together in the interior of the helix bundle. In general, the fifth and seventh residues (the e and g positions) have opposing charges and form a salt bridge stabilized by electrostatic interactions. Fibrous proteins such as keratin or the "stalks" of myosin or kinesin often adopt coiled-coil structures, as do several dimerizing proteins. A pair of coiled-coils – a four-helix bundle – is a very common structural motif in proteins. For example, it occurs in human growth hormone and several varieties of cytochrome. The Rop protein, which promotes plasmid replication in bacteria, is an interesting case in which a single polypeptide forms a coiled-coil and two monomers assemble to form a four-helix bundle.
The apical membrane or luminal membrane of a polarized cell is the surface of the plasma membrane that faces inward to the lumen. This is particularly evident in epithelial and endothelial cells, but also describes other polarized cells, such as neurons. The basolateral membrane or basolateral cell membrane of a polarized cell is the surface of the plasma membrane that forms its basal and lateral surfaces. It faces outwards, towards the interstitium, and away from the lumen. Basolateral membrane is a compound phrase referring to the terms "basal (base) membrane" and "lateral (side) membrane", which, especially in epithelial cells, are identical in composition and activity. Proteins (such as ion channels and pumps) are free to move from the basal to the lateral surface of the cell or vice versa in accordance with the fluid mosaic model. Tight junctions join epithelial cells near their apical surface to prevent the migration of proteins from the basolateral membrane to the apical membrane. The basal and lateral surfaces thus remain roughly equivalent to one another, yet distinct from the apical surface.
Sources: en.wikipedia.org
An analytical ultracentrifuge has a light source and optical detectors. To allow the light to pass through the analyte during the ultracentrifuge run, specialized cells are required which have to meet high optical standards as well as to resist the centrifugal forces. Each cell consists of a housing, two windows made from optically pure quartz glass, and a centrepiece with one or two sectors and filling holes for the sector(s), closed with a screw plug in the housing. These cell are placed into a rotor cavity with a continuous bore, with a collar at the bottom to retain the cell. By applying specific equipment and adapting measurement parameters several types of experiments can be performed. Most common AUC experiments are sedimentation velocity and sedimentation equilibrium experiments.
The source of ADP-ribose for most enzymes that perform this modification is the redox cofactor NAD+. In this transfer reaction, the N-glycosidic bond of NAD+ that bridges the ADP-ribose molecule and the nicotinamide group is cleaved, followed by nucleophilic attack by the target amino acid side chain. (ADP-ribosyl)transferases can perform two types of modifications: mono(ADP-ribosyl)ation and poly(ADP-ribosyl)ation.
Scleroderma, polymyositis, and dermatomyositis elicit little or no CRP response. CRP levels also tend to remain low despite inflammatory activity in systemic lupus erythematosus (SLE) unless serositis or synovitis is present. This may be explained by increased levels of type I IFN in SLE, since type I IFN (i.e IFN alpha) inhibits hepatic CRP production. A polymorphisms of the CRP gene which cause lower CRP levels is also more frequent in SLE patients compared with controls. Elevations of CRP in the absence of clinically significant inflammation can occur in kidney failure. CRP level is an independent risk factor for atherosclerotic disease. Patients with high CRP concentrations are more likely to develop stroke, myocardial infarction, and severe peripheral vascular disease. Elevated level of CRP can also be observed in inflammatory bowel disease (IBD), including Crohn's disease and ulcerative colitis. High levels of CRP has been associated to point mutation Cys130Arg in the APOE gene, coding for apolipoprotein E, establishing a link between lipid values and inflammatory markers modulation.
Sources: en.wikipedia.org
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.
An HPLC method is typically validated before its routine use and revalidated in part when significant changes affect the method. Regulators do not set a universal calendar interval. The need for revalidation depends on the change, its risk, and the applicable guidance.
Validation establishes that a method is suitable for its intended purpose, often through a planned study. Verification confirms that a laboratory can reproduce a previously validated or compendial method under its own conditions. Verification is usually narrower than full validation.
System suitability is a set of checks that confirm the instrument and method perform within limits before sample analysis. It typically includes resolution, tailing factor, retention time, and peak area reproducibility. If a check fails, the run is invalidated until the cause is resolved.