This is a working overview of retention time, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2025-09-16. Anything still debated is marked as such rather than presented as settled.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
| Property | Value | Notes |
|---|---|---|
| Abbreviation | HPLC | Also called high-performance liquid chromatography |
| Separation mechanism | Differential partitioning | Compounds distribute between mobile and stationary phases |
| Typical column chemistry | C18 (octadecylsilane) | Used in reversed-phase separations |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is common for trace and confirmatory work |
| Typical particle size | 1.8–5 µm | Smaller particles require higher pressure and can improve speed |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Protein Data Bank (PDB) is a database of three dimensional structures of biological macromolecules, such as proteins and nucleic acids. The data are typically obtained by X-ray crystallography or nuclear magnetic resonance spectroscopy (NMR spectroscopy), and submitted manually by structural biologists worldwide through PDB member organizations – PDBe, RCSB, PDBj and BMRB. The database can be accessed through the webpages of its members, including PDBe (housed at the EMBL-EBI). As a member of the Worldwide Protein Data Bank (wwPDB) consortium, PDBe aids in the joint mission of archiving and maintenance of macromolecular structure data.
High rates of cardiovascular disease creates a high demand for grafts for vascular bypass surgery, especially small-diameter grafts which prevent occlusion. Modifying vascular tissue grafts with RGD has been shown to inhibit platelet adhesion, improve cell infiltration and enhance endothelialization. There have also been efforts to regenerate damaged heart tissues by applying cardiac patches following myocardial infarction. The addition of RGD onto a cardiac tissue scaffold has been shown to promote cell adhesion, prevent apoptosis and enhance tissue regeneration. RGD peptide has also been used to improve endothelial cell adhesion and proliferation on synthetic heart valves.
The major limitation in the development of artificial WBCs is the translation of the technologies into clinical approval and use. Other limitations include the availability of technology necessary to produce artificial WBCs, variability in yield, and difficulties in purifying the particles necessary for standard clinical use. Some studies have also found that these particles may unintentionally target other tissues that are otherwise healthy. The delivery of the therapies faces some difficulties in that too rapid administration might cause systemic side effects, whereas a too slow release would be less effective. A major limitation to polymersomes is that a select number of polymers such as polyethylene glycol and poly(lactic-co-glycolic acid) are approved by the FDA for clinical use. Nanoghosts, or more generally membrane-coated nanoparticles, experience limitations in that cells will have varying degrees of proteins present in their membranes, creating variability and lack of stability in those products. There also is the risk that membrane proteins essential to the biomimetic function of the nanoghosts can become denatured in the manufacturing and storage process. Overall, more studies need to be done on these biomimetic solutions to verify efficacy and safety.
Aβ is the main component of the kind of amyloid plaques that form in the brains of people with Alzheimer's disease. Aβ can also form the deposits that line cerebral blood vessels in cerebral amyloid angiopathy. The plaques are composed of aggregated Aβ oligomers called amyloid fibrils, a protein fold shared by other peptides such as the prions associated with protein misfolding disease, also known as proteinopathy.
Abelacimab (MAA868), is a fully human monoclonal antibody for the treatment of thrombosis, under development by Anthos Therapeutics. It is anti-factor XI antibody. The hope behind its development is that factor XI plays a bigger role in thrombosis (via the intrinsic/contact activation pathway) than hemostasis, so targeting it might reduce clotting risks without a corresponding increase in bleeding. It has, indeed, shown overwhelming reduction in bleeding as compared to a direct oral anticoagulant (rivaroxaban) in patients with atrial fibrillation and a moderate-to-high risk of stroke. Data is insufficient for drawing a conclusion on whether it increases or decreases stroke events as compared to rivaroxaban. Antibody Monoclonal antibody Immunology
Sources: en.wikipedia.org
The psi-loop (Ψ-loop) motif consists of two antiparallel strands with one strand in between that is connected to both by hydrogen bonds. There are four possible strand topologies for single Ψ-loops. This motif is rare as the process resulting in its formation seems unlikely to occur during protein folding. The Ψ-loop was first identified in the aspartic protease family. β-sheets are present in all-β, α+β and α/β domains, and in many peptides or small proteins with poorly defined overall architecture. All-β domains may form β-barrels, β-sandwiches, β-prisms, β-propellers, and β-helices.
Atoltivimab/maftivimab/odesivimab, sold under the brand name INMAZEB, is a fixed-dose combination of three monoclonal antibodies for the treatment of ebola caused by Zaire ebolavirus. It was developed by Regeneron Pharmaceuticals and contains three human monoclonal antibodies, atoltivimab, maftivimab, and odesivimab-ebgn. The most common side effects include fever, chills, tachycardia (fast heart rate), tachypnea (fast breathing), and vomiting; however, these are also common symptoms of Ebola virus infection. Atoltivimab/maftivimab/odesivimab is the first FDA-approved treatment for Zaire ebolavirus. Atoltivimab/maftivimab/odesivimab was approved for medical use in the United States in October 2020. The U.S. Food and Drug Administration (FDA) considers it to be a first-in-class medication. It is on the World Health Organization's List of Essential Medicines. Atoltivimab/maftivimab/odesivimab is indicated for the treatment of infection caused by Zaire ebolavirus.
Bruce Randall Donald (born 1958) is an American computer scientist and computational biologist. He is the James B. Duke Professor of Computer Science and Biochemistry at Duke University. He has made numerous contributions to several fields in Computer Science such as robotics, Microelectromechanical Systems (MEMS), Geometric & physical algorithms and computational geometry, as well as in areas of Structural Molecular Biology & Biochemistry such as Protein design, Protein Structure Determination and Computational Chemistry.
AST is similar to alanine transaminase (ALT) in that both enzymes are associated with liver parenchymal cells. The difference is that ALT is found predominantly in the liver, with clinically negligible quantities found in the kidneys, heart, and skeletal muscle, while AST is found in the liver, heart (cardiac muscle), skeletal muscle, kidneys, brain, and red blood cells. As a result, ALT is a more specific indicator of liver inflammation than AST, as AST may be elevated also in diseases affecting other organs, such as myocardial infarction, acute pancreatitis, acute hemolytic anemia, severe burns, acute renal disease, musculoskeletal diseases, and trauma. The elevated AST level in hemorrhagic fever caused by crimean-congo hemorrhagic fever virus is associated with high mortality rate. AST was defined as a biochemical marker for the diagnosis of acute myocardial infarction in 1954. However, the use of AST for such a diagnosis is now redundant and has been superseded by the cardiac troponins. Laboratory tests should always be interpreted using the reference range from the laboratory that performed the test. Example reference ranges are shown below:
Sources: en.wikipedia.org
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.
In most cases the sample is consumed or altered during analysis, though some detectors are non-destructive. Fractions can be collected after separation for further study. Repeated testing therefore requires additional sample.
Run times range from under a minute for fast methods to over an hour for complex separations. Sample preparation, equilibration, and data review add time. Throughput depends on instrument configuration and method requirements.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.