High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
AS9100 Revision C (2009), Quality Management System – Requirements for Aviation, Space and Defense Organizations The update of AS9100 from revision B to C is largely to address the following question: "Our supplier is repeatedly late on delivery and failing to meet our requirements, how is it possible that they still have their AS9100 certificate?" That is, the AS9100C changes are driven by repeated delivery of non-conforming product and repeated late delivery by organizations that held AS9100A/B certifications. Those organizations had documented controls that conformed to the standard, however, there were insufficient processes in place to assure effectiveness of those controls. The response in this AS9100 revision is to elevate the requirements for Risk Management and to make Risk Management an integrated theme throughout the standard. A major challenge to AS9100B-compliant organizations was the new AS9100 auditing standards defined in AS9101 Revision D, which eliminates the clause-based compliance checklist and requires organizations to provide evidence of effectiveness of their systems and processes. Summary of changes between AS9100B and AS9100C:
==== Hybrid Closed Loop (HCL) / Advanced Hybrid Closed Loop (AHCL) ==== Hybrid closed loop (HCL) systems further expand on the capabilities of PLGS systems by adjusting basal insulin delivery rates both up and down in response to values from a continuous glucose monitor. Through this modulation of basal insulin, the system is able to reduce the magnitude and duration both hyperglycemic and hypoglycemic events. Users still must initiate manual mealtime boluses. Advanced hybrid closed loop systems have advanced algorithms. Fully Closed Loop (FCL) Fully or full closed loop (FCL) systems adjust insulin delivery in response to changes in glucose levels without requiring input by users for mealtime insulin or announcements of meals.
APCs naturally have a role in fighting tumors, via stimulation of B and cytotoxic T cells to respectively produce antibodies against tumor-related antigen and kill malignant cells. Dendritic cells, presenting tumor-specific antigen to T cells, are key to this process. Cancer therapies have included treating the patient with increased numbers of dendritic cells or cancer-specific T cells. However, newer therapies have turned to genetically engineered artificial antigen-presenting cells designed to prime the immune system to attack malignant cells. Some artificial APCs are derived from human cells; others are acellular, containing MHC proteins, co-stimulatory molecules and the necessary peptides. The APC activator IMP321 is being tested in clinical trials to accelerate the immune reaction to eliminate metastatic breast cancer or melanoma. Antigen: protease degradation on YouTube – PMAP animation Antigen-Presenting+Cells at the U.S. National Library of Medicine Medical Subject Headings (MeSH)
From the 17th century, and before modern developments in organic chemistry nomenclature, acetone was given many different names. They included "spirit of Saturn", which was given when it was thought to be a compound of lead and, later, "pyro-acetic spirit" and "pyro-acetic ester". Prior to the name "acetone" being coined by French chemists, it was named "mesit" (from the Greek μεσίτης, meaning mediator) by Carl Reichenbach, who also said that methyl alcohol consisted of mesit and ethyl alcohol. Names derived from mesit include mesitylene and mesityl oxide which were first synthesised from acetone. In 1839, the name "acetone" began to be used, because it was obtained from acetic acid. Unlike many compounds with the acet- prefix which have a 2-carbon chain, acetone has a 3-carbon chain. That has caused confusion because there can not be a ketone with 2 carbons. The prefix refers to acetone's relation to vinegar (acetum in Latin, also the source of the words "acid" and "acetic"), rather than its chemical structure.
Sources: en.wikipedia.org
Essentially all of the studies on 5-oxo-ETE's activities and target cells, similar to those on other members of the 5(S)-HETE family of agonists, are best classified as pre-clinical development studies: they have not yet been determined to be important in human pathophysiology. Translation studies are needed to learn if the preclinical studies implicating 5-Oxo-ETE and other 5(S)-HETE family members in allergic diseases, inflammatory diseases, cancer, steroid production, bone remodeling, parturition, and other pathophysiological events, as outlined here and on the 5-HETE page, are relevant to humans and therefore of clinical significance.
an intermediate or building block in the synthesis of non-ionic and other surfactants and related functional additives; a component of lubricant and plastic additive systems, including thermoplastic polyurethanes, where long-chain alcohols are used to modify flexibility and permeability; a minor constituent of policosanol-type mixtures employed in cosmetics and personal-care products as part of the lipid phase of creams and emulsions. Because of its chain length and structural similarity to other fatty alcohols, 1-heneicosanol is also used as a reference compound and analytical standard in studies of plant waxes, policosanol mixtures and related lipid fractions. Available safety data sheets describe 1-heneicosanol as a low-volatility solid that is not classified as hazardous under European CLP regulations, but which may cause mild irritation to the skin, eyes and respiratory tract on contact or inhalation of dust. Standard laboratory precautions such as avoiding dust formation, using local exhaust ventilation and wearing eye and skin protection are recommended.
Josh Allen became the first player to score a rushing touchdown, a receiving touchdown and multiple passing touchdowns in a single game. Bobby Wagner extended his streak of recording 100 tackles in a season to 13 years. He is the second player to record the feat, joining London Fletcher. Jayden Daniels became the first rookie to complete 80 percent of his passes, throw three touchdowns, and run for a touchdown in a single game. Jameis Winston became the first player in the Super Bowl era to have at least 400 passing yards, four passing touchdowns and two interceptions returned for touchdowns in a game. Justin Herbert became the third player to have at least 10 consecutive games without interception (minimum 15 attempts per game), joining Tom Brady and Derek Carr. The Pittsburgh Steelers tied the record for most consecutive seasons finishing with a winning percentage of .500 or better, with 21. They share the record with the Dallas Cowboys, who did so from 1965 to 1985. The Cincinnati Bengals tied the single-season record for most games lost while scoring at least 30 points, with four. They share the record with the 2002 Kansas City Chiefs. Week 14
Sources: en.wikipedia.org
Affimer proteins were developed initially at the MRC Cancer Cell Unit in Cambridge then across two laboratories at the University of Leeds. Derived from the cysteine protease inhibitor family of cystatins, which function in nature as cysteine protease inhibitors, these 12–14 kDa proteins share the common tertiary structure of an alpha-helix lying on top of an anti-parallel beta-sheet. Affimer proteins display two peptide loops that can all be randomized to bind to desired target proteins, in a similar manner to monoclonal antibodies. Stabilization of the two peptides by the protein scaffold constrains the possible conformations that the peptides can take. This increases the binding affinity and specificity compared to libraries of free peptides, though can limit the target repertoire of Affimers.
The predecessor to the CAD, termed an evaporative electrical detector, was first described by Kaufman in 2002 at TSI Inc in US patent 6,568,245 and was based on the coupling of liquid chromatographic approaches to TSI's electrical aerosol measurement (EAM) technology. At around the same time Dixon and Peterson at California State University were investigating the coupling of liquid chromatography to an earlier version of TSI's EAM technology, which they called an aerosol charge detector. Subsequent collaboration between TSI and ESA Biosciences Inc. (now part of Thermo Fisher Scientific), led to the first commercial instrument, the Corona CAD, which received both the Pittsburgh Conference Silver Pittcon Editor's Award (2005) and R&D 100 award (2005). Continued research and engineering improvements in product design resulted in CADs with ever increasing capabilities. The newest iterations of the CAD are the Thermo Scientific Corona Veo Charged Aerosol Detector, Corona Veo RS Charged Aerosol Detector and Thermo Scientific Vanquish Charged Aerosol Detectors.
It is thought that high glucagon levels and lack of insulin production are the main triggers for the metabolic issues associated with Type I diabetes, in particular maintaining normal blood glucose levels, formation of ketone bodies, and formation of urea. One finding of note is that the glucagon response to hypoglycemia is completely absent in patients with Type I diabetes. Consistently high glucagon concentrations in the blood can lead to diabetic ketoacidosis, which is when ketones from lipid breakdown build up in the blood, which can lead to dangerously low blood glucose levels, low potassium levels, and in extreme cases cerebral edema. It has been proposed that the reason for the high levels of glucagon found in the plasma of patients with Type I diabetes is the absence of beta cells producing insulin and the reciprocal effect this has on delta cells and the secretion of somatostatin.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.