If you have been reading about Chromatogram and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2025-08-22. Where a claim depends on a specific study, the study is described rather than over-claimed.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
To meet the NADPH and ATP demands in the mesophyll and bundle sheath, light needs to be harvested and shared between two distinct electron transfer chains. ATP may be produced in the bundle sheath mainly through cyclic electron flow around Photosystem I, or in the mesophyll mainly through linear electron flow, depending on the light available in the bundle sheath or in the mesophyll. The relative requirement of ATP and NADPH in each type of cell will depend on the photosynthetic subtype. The apportioning of excitation energy between the two cell types will influence the availability of ATP and NADPH in the mesophyll and bundle sheath. For instance, green light is not strongly adsorbed by mesophyll cells and can preferentially excite bundle sheath cells, or vice versa for blue light. Because bundle sheaths are surrounded by mesophyll, light harvesting in the mesophyll will reduce the light available to reach bundle sheath cells. Also, the bundle sheath size limits the amount of light that can be harvested.
Large AGE proteins unable to enter the Bowman's capsule are capable of binding to receptors on endothelial and mesangial cells and to the mesangial matrix. Activation of RAGE induces production of a variety of cytokines, including TNFβ, which mediates an inhibition of metalloproteinase and increases production of mesangial matrix, leading to glomerulosclerosis and decreasing kidney function in patients with unusually high AGE levels. Peptides and free adducts, the only breakdown products of AGE that are suitable for urinary excretion, are more aggressive than the AGE proteins from which they are derived, and they can perpetuate related pathology in people with diabetes, even after hyperglycemia has been brought under control.
Large AGE proteins unable to enter the Bowman's capsule are capable of binding to receptors on endothelial and mesangial cells and to the mesangial matrix. Activation of RAGE induces production of a variety of cytokines, including TNFβ, which mediates an inhibition of metalloproteinase and increases production of mesangial matrix, leading to glomerulosclerosis and decreasing kidney function in patients with unusually high AGE levels. Peptides and free adducts, the only breakdown products of AGE that are suitable for urinary excretion, are more aggressive than the AGE proteins from which they are derived, and they can perpetuate related pathology in people with diabetes, even after hyperglycemia has been brought under control.
In botany, apical dominance is the phenomenon whereby the main, central stem of the plant is dominant over (i.e., grows more strongly than) other side stems; on a branch the main stem of the branch is further dominant over its own side twigs. Plant physiology describes apical dominance as the control exerted by the terminal bud (and shoot apex) over the outgrowth of lateral buds.
Sources: en.wikipedia.org
ABC transporters utilize the energy of ATP binding and hydrolysis to transport various substrates across cellular membranes. They are divided into three main functional categories. In prokaryotes, importers mediate the uptake of nutrients into the cell. The substrates that can be transported include ions, amino acids, peptides, sugars, and other molecules that are mostly hydrophilic. The membrane-spanning region of the ABC transporter protects hydrophilic substrates from the lipids of the membrane bilayer thus providing a pathway across the cell membrane. Eukaryotes do not possess any importers. Exporters or effluxers, which are present both in prokaryotes and eukaryotes, function as pumps that extrude toxins and drugs out of the cell. In gram-negative bacteria, exporters transport lipids and some polysaccharides from the cytoplasm to the periplasm. The third subgroup of ABC proteins do not function as transporters, but are rather involved in translation and DNA repair processes.
All the proteolytic activity of the asparagine peptide lyases is only self-cleavages, then no further peptidase activity occurs. The main residue of the active site is the asparagine and there are other residues involved in the catalytic mechanism, which are different between the different families of asparagine peptide lyases. The cleavage mechanism consists in the cyclization of the asparagine, assisted by other active site residues. In certain conditions, the asparagine cyclic structure nucleophilically attacks its C-terminal peptide bond to the main chain forming a new bond to create a stable succinimide, cleaving itself from the main chain and consequently releasing the two halves of the product. No inhibitors are known.
Alanine (symbol Ala or A), or α-alanine, is an α-amino acid that is used in the biosynthesis of proteins. It contains an amine group and a carboxylic acid group, both attached to the central carbon atom which also carries a methyl group side chain. Consequently it is classified as a non-polar, aliphatic α-amino acid. Under biological conditions, alanine exists in its zwitterionic form with its amine group protonated (as −NH+3) and its carboxyl group deprotonated (as −CO−2). Alanine is encoded by all codons starting with GC (GCU, GCC, GCA, and GCG). The L-isomer of alanine (left-handed) is the one that is incorporated into proteins. L-alanine is second only to L-leucine in rate of occurrence, accounting for 7.8% of the primary structure in a sample of 1,150 proteins. The right-handed form, D-alanine, occurs in peptides in some bacterial cell walls (in peptidoglycan) and in some peptide antibiotics, and occurs in the tissues of many crustaceans and molluscs as an osmolyte. Alanine is not an essential amino acid in humans because it can be synthesized metabolically and does not need to be present in the diet. However hypoalaninemia (alanine deficiency) is possible under certain conditions such as ketotic hypoglycemia.
Aspartic acid was first discovered in 1827 by Auguste-Arthur Plisson and Étienne-Ossian Henry by hydrolysis of asparagine, which had been isolated from asparagus juice in 1806. Their original method used lead hydroxide, but various other acids or bases are now more commonly used instead. There are two forms or enantiomers of aspartic acid. The name "aspartic acid" can refer to either enantiomer or a mixture of two. Of these two forms, only one, "L-aspartic acid", is directly incorporated into proteins. The biological roles of its counterpart, "D-aspartic acid" are more limited. Where enzymatic synthesis will produce one or the other, most chemical syntheses will produce both forms, "DL-aspartic acid", known as a racemic mixture. In the human body, aspartate is most frequently synthesized through the transamination of oxaloacetate. The biosynthesis of aspartate is facilitated by an aminotransferase enzyme: the transfer of an amine group from another molecule such as alanine or glutamine yields aspartate and an alpha-keto acid.
Some anesthetics and chemotherapy drugs are injected intrathecally into the subarachnoid space, where they spread around CSF, meaning substances that cannot cross the blood–brain barrier can still be active throughout the central nervous system. Baricity refers to the density of a substance compared to the density of human cerebrospinal fluid and is used in regional anesthesia to determine the manner in which a particular drug will spread in the intrathecal space. Liquorpheresis is the process of filtering the CSF in order to clear it from endogen or exogen pathogens. It can be achieved by means of fully implantable or extracorporeal devices, though the technique remains experimental today.
Sources: en.wikipedia.org
A rare development is amyloid purpura, a susceptibility to bleeding with bruising around the eyes, termed "raccoon-eyes". Amyloid purpura is caused by amyloid deposition in the blood vessels and reduced activity of thrombin and factor X, two clotting proteins that lose their function after binding with amyloid. Amyloid deposits in tissue can cause enlargement of structures. Twenty percent of people with AL amyloidosis have an enlarged tongue, that can lead to obstructive sleep apnea, difficulty swallowing, and altered taste. Tongue enlargement does not occur in ATTR or AA amyloidosis. Deposition of amyloid in the throat can cause hoarseness.
Apamin is an 18 amino acid globular peptide neurotoxin found in apitoxin (bee venom). Dry bee venom consists of 2–3% of apamin. Apamin selectively blocks SK channels, a type of Ca2+-activated K+ channel expressed in the central nervous system. Toxicity is caused by only a few amino acids, in particular cysteine1, lysine4, arginine13, arginine14 and histidine18. These amino acids are involved in the binding of apamin to the Ca2+-activated K+ channel. Due to its specificity for SK channels, apamin is used as a drug in biomedical research to study the electrical properties of SK channels and their role in the afterhyperpolarizations occurring immediately following an action potential.
Bone morphogenetic proteins (BMPs) are a group of growth factors also known as cytokines and as metabologens. Professor Marshall Urist and Professor Hari Reddi discovered their ability to induce the formation of bone and cartilage, BMPs are now considered to constitute a group of pivotal morphogenetic signals, orchestrating tissue architecture throughout the body. The important functioning of BMP signals in physiology is emphasized by the multitude of roles for dysregulated BMP signalling in pathological processes. Cancerous disease often involves misregulation of the BMP signalling system. Absence of BMP signalling is, for instance, an important factor in the progression of colon cancer, and conversely, overactivation of BMP signalling following reflux-induced esophagitis provokes Barrett's esophagus and is thus instrumental in the development of esophageal adenocarcinoma. Recombinant human BMPs (rhBMPs) are used in orthopedic applications such as spinal fusions, nonunions, and oral surgery. rhBMP-2 and rhBMP-7 are Food and Drug Administration (FDA)-approved for some uses. rhBMP-2 causes more overgrown bone than any other BMPs and is widely used off-label.
Arthur 'Blaine' Bowman (born 1946 in Ogden, Utah, USA) is a leading proponent of ion chromatography, who has served variously as chairman, president, chief executive officer, and director of Dionex Corporation, a manufacturer of analytical instruments. Bowman received the 2015 Pittcon Heritage Award in recognition of his contributions to the field of ion chromatography. Arthur 'Blaine' Bowman was born in 1946 in Ogden, Utah, US. Around age 10, his family moved to Southern California, where he grew up. Bowman attended Brigham Young University in Provo, Utah in the physics program. As an undergraduate, he worked in the summer as an engineer at McDonnell Douglas, testing modules for the Apollo rocket. Bowman received his B.S. in physics in 1970. Next, Bowman worked as a product engineer at Motorola's Semiconductor Products Division in Phoenix, Arizona, where he became interested in business. He attended Stanford University's school of business from 1971 to 1973, receiving his M.B.A. in 1973. He then joined McKinsey & Company as a management consultant.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.