If you have been reading about retention time and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-08-22. Numbers and descriptions here follow the published literature rather than marketing material.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
| Property | Value | Notes |
|---|---|---|
| Accuracy | Recovery near 100% | Depends on acceptance criteria and matrix |
| Precision | Relative standard deviation | Often at or below 2% for replicate injections |
| Limit of detection | Signal-to-noise ratio 3:1 | Approximate and method-specific |
| Limit of quantitation | Signal-to-noise ratio 10:1 | Confirmed by precision and accuracy |
| Resolution | 1.5 or greater | Typical system suitability target |
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
As a practical matter, when platinum group metals are purified through dissolution in aqua regia, gold (commonly associated with PGMs) is precipitated by treatment with iron(II) chloride. Platinum in the filtrate, as hexachloroplatinate(IV), is converted to ammonium hexachloroplatinate by the addition of ammonium chloride. This ammonium salt is extremely insoluble, and it can be filtered off. Ignition (strong heating) converts it to platinum metal: 3 [NH4]2[PtCl6] → 3 Pt + 2 N2 + 2 [NH4]Cl + 16 HCl Unprecipitated hexachloroplatinate(IV) is reduced with elemental zinc, and a similar method is suitable for small scale recovery of platinum from laboratory residues. Aqua regia reacts with tin to form tin(IV) chloride, containing tin in its highest oxidation state: 4 HCl + 2 HNO3 + Sn → SnCl4 + NO2 + NO + 3 H2O Aqua regia can react with iron pyrite to form iron(III) chloride: FeS2 + 5 HNO3 + 3 HCl → FeCl3 + 2 H2SO4 + 5 NO + 2 H2O
The 1961 Goldsboro B-52 crash was an aviation accident that occurred near Goldsboro, North Carolina, United States, on 24 January 1961. A Boeing B-52 Stratofortress carrying two 3.8-megaton Mark 39 nuclear bombs broke up in mid-air, dropping its nuclear payload in the process. Five crewmen successfully ejected or bailed out of the aircraft and landed safely; another ejected, but did not survive the landing, and two of them were killed in the crash. The accident is one of the most famous "Broken Arrow" nuclear accidents of the Cold War. Both of the weapons began their firing sequences upon separation from the aircraft, despite safeguards meant to prevent that from occurring. One of its nuclear bombs was judged by nuclear weapons engineers at the time to have been only one safety switch away from detonation, and that it was "credible" to imagine conditions under which it could have detonated. The other bomb did not get as far into its firing sequence, but became deeply embedded in a muddy field, and one of its major weapons components (the thermonuclear "secondary" stage) was regarded as irrecoverably lost after an extensive, failed effort to recover it.
Treating Type 2 Diabetes with glucose mimetics Mason found the common denominator between gastric and intestinal bypass when treating type 2 diabetes in 1998. The exposure of the distal bowel to glucose or other stimulants such as glucose mimetics resulted in the secretion of GLP-1 (glucagon-like peptide-1) hormones, which could potentially treat diabetes type-2 disease. Gastric bypass surgery treated type-2 diabetes through weight loss and the release of GLP-1 hormones. To treat diabetes-type 2 patients without surgery, he thought that using a form of glucose substitute or glucose mimetic that would reach the distal ileum before it was absorbed could be a simple and cost-effective treatment. He suggested using glucose mimetic d-tagatose in addition to weight reduction with a proper diet and increased physical activity.
Sources: en.wikipedia.org
Automated iterative homologation enables stepwise construction of carbon chains through repeated one-carbon extensions of boronic esters. Two reactions adapted to automation are the Matteson homologation, which inserts a methylene unit via chloromethyllithium, and chiral carbenoid homologation, which uses lithiated benzoate esters. Both methods have been implemented on robotic platforms under low-temperature, inert conditions. Using these techniques, up to six consecutive C(sp³)–C(sp³) bond-forming homologations have been performed without manual intervention, representing the highest number reported in an automated synthesis. The approach has also been applied to the synthesis of intermediates of the natural product (+)-kalkitoxin.
C4H2N2O4 + GSH → C4H3N2O4• + GS• C4H3N2O4• + GSH → C4H4N2O4 + GS• C4H4N2O4 + O2 → C4H3N2O4• + O2•− + H+ C4H3N2O4• + O2 → C4H2N2O4 + O2•− + H+ Because it selectively kills the insulin-producing beta-cells found in the pancreas, alloxan is used to induce diabetes in laboratory animals. This occurs most likely because of selective uptake of the compound due to its structural similarity to glucose as well as the beta-cell's highly efficient uptake mechanism (GLUT2). In addition, alloxan has a high affinity to SH-containing cellular compounds and, as a result, reduces glutathione content. Furthermore, alloxan inhibits glucokinase, a SH-containing protein essential for insulin secretion induced by glucose. Most studies have shown that alloxan is not toxic to the human beta-cell, even in very high doses, probably because of differing glucose uptake mechanisms in humans and rodents. Alloxan is, however, toxic to the liver and the kidneys in high doses, as these are tissues where the GLUT2 transporter is expressed in humans. Streptozotocin
Adenosine triphosphate (ATP) is a nucleoside triphosphate that provides free energy of approximately 58 kJ/mol (0.6 eV) to drive and support many processes in living cells, such as muscle contraction, nerve impulse propagation, and chemical synthesis. Found in all known forms of life, it is often referred to as the "molecular unit of currency" for intracellular energy transfer. When consumed in a metabolic process, ATP converts either to adenosine diphosphate (ADP) or to adenosine monophosphate (AMP). Other processes, such as oxidative phosphorylation or substrate-level phosphorylation, regenerate ATP. ATP is also a precursor to DNA and RNA, and is used as a coenzyme. Daily, an average adult human recycles through synthesis and hydrolysis around 50 kilograms of ATP (about 100 moles). From the perspective of biochemistry, ATP is classified as a nucleoside triphosphate, which indicates that it consists of three components: a nitrogenous base (adenine), the sugar ribose, and the triphosphate.
Accumulation of amyloid proteins in the gastrointestinal system may be caused by a wide range of amyloid disorders and have different presentations depending on the degree of organ involvement. Potential symptoms include weight loss, diarrhea, abdominal pain, heartburn (gastrointestinal reflux), and GI bleeding. Amyloidosis may also affect accessory digestive organs including the liver, and may present with jaundice, fatty stool, anorexia, fluid buildup in the abdomen, and spleen enlargement. Accumulation of amyloid proteins in the liver can lead to elevations in serum aminotransferases and alkaline phosphatase, two biomarkers of liver injury, which is seen in about one third of people. Liver enlargement is common. In contrast, spleen enlargement is rare, occurring in 5% of people. Splenic dysfunction, leading to the presence of Howell-Jolly bodies on blood smear, occurs in 24% of people with amyloidosis. Malabsorption is seen in 8.5% of AL amyloidosis and 2.4% of AA amyloidosis. One suggested mechanism for the observed malabsorption is that amyloid deposits in the tips of intestinal villi (fingerlike projections that increase the intestinal area available for absorption of food), begin to erode the functionality of the villi, presenting a sprue-like picture.
Sources: en.wikipedia.org
After the Netherlands in World War II in 1945, Korvezee returned to Delft, initially serving as a curator and, from 1948, as a lecturer in theoretical chemistry. Although an expert in radioactivity, she had no role in the planning of the reactor center later built on the university's grounds. When the chair became vacant following Scheffer's retirement, Korvezee was passed over once more. In 1954, the Department of Chemical Technology created an extraordinary professorship for her in the emerging field of theoretical chemistry largely regarded as compensation for the chairs she had earlier missed. Her appointment on 14 April 1954, making her the first female professor at Delft, received extensive press coverage. As a full professor, however, she retained the salary of her former lectureship. As professor, Korvezee supervised doctoral and master's students and published more than forty scientific works before 1940, many co-authored with fellow female assistants. She was a member of the Association of Women with an Academic Education (VVAO), though she was never actively involved in the women's movement despite being widely regarded as a feminist figure.
Bodybuilders may supplement their diets with protein for reasons of convenience, lower cost (relative to meat and fish products), ease of preparation, and to avoid the concurrent consumption of carbohydrates and fats. Additionally, some argue that bodybuilders, by virtue of their unique training and goals, require higher-than-average quantities of protein to support maximal muscle growth. While the recommended dietary allowance is much less, Harvard Medical School points out in Harvard Health Publishing that this RDA (recommended daily allowance) is “the minimum amount you need to keep from getting sick — not the specific amount you are supposed to eat every day.” Protein supplements are sold in ready-to-drink health shakes, bars, meal replacement products (see below), bites, oats, gels and powders. Protein powders are the most popular and may have flavoring added for palatability. The powder is usually mixed with water, milk or fruit juice and is generally consumed immediately before and after exercising or in place of a meal. The sources of protein are as follows and differ in protein quality depending on their amino acid profile and digestibility:
Increased blood CRP levels were higher in people with avian flu H7N9 compared to those with H1N1 (more common) influenza, with a review reporting that severe H1N1 influenza had elevated CRP. In 2020, people infected with COVID-19 in Wuhan, China, had elevated CRP. MedlinePlus Encyclopedia: C-reactive protein Inflammation, Heart Disease and Stroke: The Role of C-Reactive Protein (American Heart Association) C-Reactive+Protein at the U.S. National Library of Medicine Medical Subject Headings (MeSH) CRP: analyte monograph - The Association for Clinical Biochemistry and Laboratory Medicine George Vrousgos, N.D. - Southern Cross University Archived 2020-02-18 at the Wayback Machine Human CRP genome location and CRP gene details page in the UCSC Genome Browser. Overview of all the structural information available in the PDB for UniProt: P02741 (C-reactive protein) at the PDBe-KB.
Volanesorsen was approved by the European Medicines Agency (EMA) for the treatment of familial chylomicronaemia syndrome in May 2019. In January 2013 mipomersen (marketed as Kynamro) was approved by the FDA for the treatment of homozygous familial hypercholesterolemia. Inotersen received FDA approval for the treatment of hereditary transthyretin-mediated amyloidosis in October 2018. The application for inotersen was granted orphan drug designation. It was developed by Ionis Pharmaceuticals and licensed to Akcea Therapeutics. Patisiran (sold under Onpattro) was developed by Alnylam Pharmaceuticals, and also approved for use in the US and EU in 2018 with orphan drug designation. Its mechanism-of-action is the active substance of small interfering RNA (siRNA), which allows it to interfere with and block the production of transthyretin. As such, it was the first FDA-approved siRNA therapeutic.
Generally speaking single-particle measurement instruments desorb particles one at a time using a pulsed laser. The process is called laser desorption/ionization (LDI) and is the primary ionization method used for single-particle measurements. The main advantage of using LDI over thermal desorption, is the ability to analyze both non-refractory and refractory (e.g., mineral dust, soot) components of atmospheric aerosols. Laser vaporization allows precise laser firing when individual particles fly through the vaporization zone, and the systems are thus dubbed single particle mass spectrometers (SPMS). Several versions of SPMS have been reported, including the aerosol time-of-flight mass spectrometer (AToFMS), the laser mass analyzer for particles in the airborne state (LAMPAS), particle analysis by laser mass spectrometer (PALMS), the rapid single-particle mass spectrometer (RSMS), the bioaerosol mass spectrometer (BAMS) b194 Steele et al., 2003), the nanoaerosol mass spectrometer (NAMS), the single-particle laser ablation time-of-flight mass spectrometer (SPLAT), the single-particle aerosol mass spectrometer (SPAMS), and laser ablation aerosol particle time-of-flight mass spectrometer (LAAP-ToF-MS). Among the most commons of these instruments is the aerosol time-of-flight mass spectrometer (AToFMS).
Sources: en.wikipedia.org
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.
Quantification usually compares detector response to a standard curve made from reference standards. The curve may be external, internal, or based on standard addition depending on matrix effects. Results are reported with units and, when required, uncertainty.
Carryover occurs when analyte from a previous injection remains in the system and appears in a later chromatogram. It can come from the injector, column, or tubing. Blank injections and needle washes help detect and reduce it.
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.