This is a working overview of Reversed phase, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-02-26 and is reviewed periodically as new material appears.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
The first automated insulin delivery system was known as the Biostator. Currently available AID systems fall into three broad classes based on their capabilities. The first systems released can only halt insulin delivery (predictive low glucose suspend) in response to already low or predicted low glucose. Hybrid Closed Loop systems can modulate delivery both up and down, although users still initiate insulin doses (boluses) for meals and typically "announce" or enter meal information. Fully Closed Loops require no manual insulin delivery actions or announcement for meals. A step forward from threshold suspend systems, predictive low glucose suspend (PLGS) systems use a mathematical model to extrapolate predicted future blood sugar levels based on recent past readings from a CGM. This allows the system to reduce or halt insulin delivery prior to a predicted hypoglycemic event.
Founded in 1984, Bio-Synthesis, Inc. was known as OCS Laboratories and was one of the first companies providing commercially available synthetic oligonucleotides to the biomedical research community worldwide. It was the first producer of commercially available synthetic DNA and became a producer of synthetic peptides in 1985, and became the only company to provide both synthetic DNA and peptide under one roof. Also in 1985 the process, now known as PCR, was discovered by Mullis et al. A key activity for Bio-Synthesis was to synthesize large number of PCR primer thus assisting and solidifying the early adoption of this now common and crucial process in biology.
Possibly the most common use of affinity chromatography is for the purification of recombinant proteins. Proteins with a known affinity are protein tagged in order to aid their purification. The protein may have been genetically modified so as to allow it to be selected for affinity binding; this is known as a fusion protein. Protein tags include hexahistidine (His), glutathione-S-transferase (GST), maltose binding protein (MBP), and the Colicin E7 variant CL7 tag. Histidine tags have an affinity for nickel, cobalt, zinc, copper and iron ions which have been immobilized by forming coordinate covalent bonds with a chelator incorporated in the stationary phase. For elution, an excess amount of a compound able to act as a metal ion ligand, such as imidazole, is used. GST has an affinity for glutathione which is commercially available immobilized as glutathione agarose. During elution, excess glutathione is used to displace the tagged protein. CL7 has an affinity and specificity for Immunity Protein 7 (Im7) which is commercially available immobilized as Im7 agarose resin. For elution, an active and site-specific protease is applied to the Im7 resin to release the tag-free protein.
Albert Cardona is a neuroscientist and connectomics researcher who is a Programme Leader at the MRC Laboratory of Molecular Biology. and a Professor at the University of Cambridge in Cambridge, UK. He is also a Fellow at Pembroke College, Cambridge. His research maps neuronal circuits with synaptic resolution using volume electron microscopy, particularly in small animals such as the Drosophila, and studies how the structure of a neural circuit relates to its function
A titration curve for a diprotic acid contains two midpoints where pH=pKa. Since there are two different Ka values, the first midpoint occurs at pH=pKa1 and the second one occurs at pH=pKa2. Each segment of the curve that contains a midpoint at its center is called the buffer region. Because the buffer regions consist of the acid and its conjugate base, it can resist pH changes when base is added until the next equivalent points.
Sources: en.wikipedia.org
The presence of autoantibodies against citrullinated proteins in rheumatoid arthritis patients was first described in the mid-1970s when the biochemical basis of antibody reactivity against keratin and filaggrin was investigated. Subsequent studies demonstrated that autoantibodies from RA patients react with a series of different citrullinated antigens, including fibrinogen, deiminated Epstein–Barr virus nuclear antigen 1 and vimentin, which is a member of the intermediate filament family of proteins. Several assays for detecting ACPAs were developed in the following years, employing mutated citrullinated Vimentin (MCV-assay), filaggrin-derived peptides (CCP-assay) and viral citrullinated peptides (VCP-assay). A 2006 clinical study showed that anti viral citrullinated peptide (VCP) antibodies of the IgG and IgA isotypes represent a discriminating specific marker of rheumatoid arthritis from other chronic arthritides and disease controls, suggesting an independent production of each isotype. In 2010, ACPA testing has become substantial part of The 2010 ACR-EULAR classification criteria for rheumatoid arthritis.
Affinity chromatography can be used in a number of applications, including nucleic acid purification, protein purification from cell free extracts, and purification from blood. By using affinity chromatography, one can separate proteins that bind to a certain fragment from proteins that do not bind that specific fragment. Because this technique of purification relies on the biological properties of the protein needed, it is a useful technique and proteins can be purified many folds in one step.
Subject of research: synthesis of organophosphorous and organoelement compounds, study of their spatial and electronic structure, intramolecular electronic interactions, reaction capacity and mechanism of reactions. Arkady N. Pudovik corresponding member of Russian Academy of Science worked at this department since its opening (1948) until his death (February 2006) he was the founder of the department of High Molecular and Organoelement Compounds and held the position of Head of department until 1987. Current head of the Department – Corresponding Member of the Academy of Sciences of the Republic of Tatarstan, Professor Vladimir I. Galkin, doctor of Science in chemistry. The Department conducts research in the following fields:
Amino acid-based formula is a type of infant milk formula made from individual amino acids. It is hypoallergenic and intended for infants suffering from severe allergy to milk and various gastrointestinal conditions, such as food protein-induced enterocolitis syndrome and malabsorption syndromes. It is sometimes referred to as elemental formula but this is considered a misleading name. Issues with the use of amino acid-based formula include its high cost and its unpalatable taste. Intake of amino-acid formula for healthy infants shows no advantage in growth.
AlphaFold 2 scoring more than 90 in CASP's global distance test (GDT) was considered a great achievement in computational biology. Nobel Prize winner and structural biologist Venki Ramakrishnan called the result "a stunning advance on the protein folding problem", adding that "It has occurred decades before many people in the field would have predicted. It will be exciting to see the many ways in which it will fundamentally change biological research." AlphaFold 2's success received wide media attention. News pieces appeared in the science press, such as Nature, Science, MIT Technology Review, and New Scientist, and the story was covered by national newspapers. A frequent theme was the ability to predict protein structures based on the constituent amino acid sequence, expected to have benefits in the life sciences—accelerating drug discovery and enabling better understanding of diseases. Some have noted that even a perfect answer to the protein prediction problem still leaves questions about the protein folding problem (and thus protein dynamics)—understanding in detail how the folding process actually occurs in nature (and how sometimes they can also misfold).
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.